MANUFACTURING SINCE 1999 · INTERNATIONAL PROJECTS
MINGAN 明安MINGAN Fire Protection TechnologyContact us ↗
Fire-resistant glazed roofs & floors

MINGAN / FIRE-RESISTANT GLAZING SYSTEMS

Fire-resistant glazed roofs & floors

Fire-rated glass skylights and flooring address horizontal or near-horizontal glazing, bringing daylight and transparency to the design while fire, structural and use-safety requirements are assessed. Skylights and walkable floors are selected for their different intended uses.

CATALOGUE TECHNICAL INFORMATIONEI60 / EI120

Laminated horizontal glazing with an insulating fire-resistant layer.

Ratings refer to the respective documented configurations.

Catalogue specifications

ProductIntegrity / insulation (min)Thickness (mm)Max. W × H (mm)
FLAMGUARD EI6060 / 60551284 × 1350
FLAMGUARD EI6060 / 60631284 × 1914
FLAMGUARD EI120120 / 120711260 × 1326
FLAMGUARD EI120120 / 120791260 × 1890

On small screens, swipe the table horizontally to see every column.

Catalogue values apply to the listed configurations. Confirm the complete assembly, dimensions, orientation, supports, fixings, seals and hardware against the applicable test or classification documents.

Glass, PVB and insulating interlayer

Glass, PVB and insulating interlayer
Chinese product handbook 2025, p. 37.View full-size drawing ↗

Options include slip-resistant surfaces for suitable floors, clear or frosted glass, and green or blue tinted glass.

Typical fire-rated floor-glass section

Typical fire-rated floor-glass section
Chinese product handbook 2025, p. 37.View full-size drawing ↗
1
Steel frame
2
Fire-resistant board
3
Fire-resistant floor glass
4
Glazing sealant
5
Fire-resistant fibre pad

Performance and project requirements

The catalogue cites BS EN 1365-2:2014 and BS EN 1363-1:2012, and describes BS 6206 Grade A impact safety for applicable glazing. During fire exposure, the interlayer forms an opaque insulating barrier.

For skylights and walkable floors, verify fire exposure direction and the specific horizontal assembly. Walkable glazing also requires checks of imposed loads, support spacing, impact and post-breakage behaviour.

Drawings are catalogue construction illustrations. Their dimensions and components describe the shown arrangement; project installation follows the approved system detail.

Typical applications

Skylights and horizontal fire-separation applications requiring daylight; transparent floors supported by dedicated structural and assembly verification.

Options to discuss

Discuss clear, frosted or coloured appearances. Walkable floors additionally require review of slip resistance, loading, impact and post-breakage safety.

Choosing the right system

Vertical partition results do not automatically apply to skylights, and a skylight configuration does not automatically establish walkable-floor suitability. Orientation and use loads must match.

Information for your project

Skylight or walkable-floor use; orientation and fire-exposed face; panels and supports; loading and service conditions; fire and safety requirements.

Related products

Project enquiry →Downloads ↓

LET’S TALK ABOUT YOUR PROJECT

How can we help?

Ask for a quotation, discuss a technical requirement or get help with an existing order.

Prefer to contact us directly?

info@minganfire.com+86 750 8383188
AddressNo. 180 Hecheng Avenue, Hecheng Town, Heshan, Guangdong, China.

* Required fields

Your information will be used to respond to this enquiry.